top of page

HAD-FLUX ]Heat Flux of Evaporator Bank Sections

This program is HAD-FlUX which is used to calculate the total heat absorption value of the evaporator (evaporator), and to know the calorific value absorbed by each bank in the direction of gas passing. The calculated values ​​are used when calculating circulation ratio, or when you want to know more closely the temperature distribution of each bank.

flux_n01.jpg

          *******************************************************************************
          *  Calculation of Evaporator bank section           0000-00                   *
          *******************************************************************************

   Customer : Project                                                        
   Service  : Floor_pressure_test_8.36_kg/cm2-a_low_pressure  

                     

   Gas Analysis (Weight Fraction)/(Volume Fraction)
       CO2      SO2      N2       H2O      O2       Ar
    0.05137  0.00000  0.73520  0.04770  0.15323  0.01250
    0.03320  0.00000  0.74640  0.07530  0.13620  0.00890

   Gas flow                     kg/hr    1496422.
   Steam flow                   kg/hr      25815.
   Heat absorbed              kcal/hr   16854000.
   Inlet temperature(Gas side)  deg C       222.3
   Outlet temperature(Gas side) deg C       178.3
   Inlet temperature(W/S side)  deg C       164.2
   Outlet temperature(W/S side) deg C       171.4
   Number of longitudinal rows                 19
   Heating Surface                 m2     15647.7
   Overall heat transfer kcal/m2-hr-c   49.018993
   Setting loss                     %      0.6000
   Blowdown rate                    %        0.00
   Enth. of Inlet Water/Steam kcal/kg        8.36
   Enth. of Sat. Water        kcal/kg      173.26
   Enth. of Sat. Steam        kcal/kg      661.23
   Oper. pressure(Sat.)    kg/cm2-abs        8.36

    SECTION         TGI         TGO       STEAM  HEAT ABSOR     TOTAL Q      TWI      TWO  Met.Temp
                (DEG-C)     (DEG-C)     (KG/HR)   (KCAL/HR)   (KCAL/HR)  (DEG-C)  (DEG-C)  (DEG-C) 
           1     222.300     217.231       2986.    1949395.    1949395.     164.     171.     176.
           2     217.231     212.662       2688.    1755052.    3704447.     164.     171.     176.
           3     212.662     208.546       2420.    1579898.    5284345.     164.     171.     175.
           4     208.546     204.838       2178.    1422116.    6706461.     164.     171.     175.
           5     204.838     201.498       1961.    1279978.    7986440.     164.     171.     175.
           6     201.498     198.491       1764.    1151989.    9138428.     164.     171.     174.
           7     198.491     195.783       1588.    1036698.   10175126.     164.     171.     174.
           8     195.783     193.344       1429.     932916.   11108042.     164.     171.     174.
           9     193.344     191.149       1286.     839474.   11947516.     164.     171.     173.
          10     191.149     189.173       1157.     755356.   12702872.     164.     171.     173.
          11     189.173     187.394       1041.     679645.   13382517.     164.     171.     173.
          12     187.394     185.794        937.     611472.   13993989.     164.     171.     173.
          13     185.794     184.353        843.     550133.   14544122.     164.     171.     173.
          14     184.353     183.057        758.     494954.   15039076.     164.     171.     173.
          15     183.057     181.890        682.     445280.   15484356.     164.     171.     173.
          16     181.890     180.840        614.     400584.   15884940.     164.     171.     172.
          17     180.840     179.896        552.     360372.   16245312.     164.     171.     172.
          18     179.896     179.046        497.     324178.   16569490.     164.     171.     172.
          19     179.046     178.281        436.     284510.   16854000.     164.     171.     172.

bottom of page